KC530     Isolated RS485 Multi Master

Specifications and Features

- RS485 (or RS232) to RS485 isolated repeater

- Support independent master 3 channels

- Excellent communication stability by isolation

       between master and slave

- Independent communication settings

       among master channels

- Effective compensation of communication stability

       by external watchdog

 

- Data : 5 ~ 8bit, Parity : No, Even and Odd, and Stop : 1 or 2

- 4-channel RS485 terminal

- Communication speed : 1200 ~ 230.4Kbps

- Power supply : +9 ~ +30VDC

- Power consumption : Max. 1.5W (100mA/15V)

- Isolation voltage : 1KV

- Operating temperature : -20 ~ +85¡É

- Dimensions : 100 x 68 x 30mm

 

Applications of KC530

 

KC530 is a repeater to embody the multi-master of RS485 communication network. KC530 can connect and control maximum 3 units of master at the same time.

 

Uses of KC530

RS485 communication network consists of a master and several units of slave. However, in order to organize various systems, the needs of monitoring and controlling the same slave unit from many places keep on increasing. In many cases the system is made exclusively according to its own communication protocol. The problem is that these systems require much initial development cost because in many cases the system is not the common product which can be used for general purpose. So KC530 is an effective auxiliary multi-master system which uses the general properties of RS485 communication protocol. KC530 is designed to operate in almost every protocol, not only for any special protocol.

 

Isolation Repeater Function Added in KC530

- KC530 function to receive weak data, and generate

      the perfect signals and transmit them by using

      micro computer inside.

- Protection circuit is applied to supplement stability of data

      communication and protection against external surge.

      It is designed so that complete communication

      stoppage will not be occurred by external watchdog

      in any cases, such as the case that MCU breaks down

      because of the surge.

 

Setting Switch on the Back

- Setting mode comes if power is supplied

      while 1 is ON and the rest are OFF on the back

- KC530 can be connected into the setting program

      through communication port. (possible for any type

      of communication port)

- Operation mode can be selected according

      to the setting values on the back.

- New settings actualizes only when power is supplied

      again after setting changes

Terminal Block

1 : TRX1+  Positive terminal of master 1

2 : TRX1-  Negative terminal of master 1

3 : TRX2+  Positive terminal of master 2

4 : TRX2-  Negative terminal of master 2

5 : TRX3+  Positive terminal of master 3

6 : TRX3-  Negative terminal of master 3

7 : TRX4+  Not used

8 : TRX4-  Not used

9 : (R) +Vs  Power +9 ~ +30V

10 : (B) GND  Power ground

 

11 : DATA+  Positive terminal of slave at isolated side

12 : DATA-  Negative terminal of slave at isolated side

13 :

14 :

15 : SH_G  Shield ground at isolated side

 

Wirings

RS485 1:1 Wiring

 

RS485 1:N Wiring

 

RS422 1:1 Wiring

 

RS422 1:N Wiring

 

     More Products

RS232 to RS422/485

     => KC520  KC521  KC525

RS422/485 Repeaters

     => KC522U KC522B KC522C KC510 KC512A KC512B KC530

USB to RS232/RS422/485

     => KC220  KC230

Fiber to RS232/422/485

     => KC120S  KC120M

PCI Cards

     => PCI520A  PCI520B  PCI520C  PCI520D

TCP/IP

     => KG30X  KG30M  KG3060

Samcheondong 1Ga 651-2 Wansangu Jeonjusi Jeonbuk 560-807 KOREA

Tel : +82-63-228-0560   Fax : +82-63-228-0561   e-mail : akorm@akorm.com   Website : www.akorm.com/comm_module

Copyright (C)   AKORM Corporation   All Rights Reserved